For the purpose of wiring regulations, bathrooms are divided into four zones, in accordance with the Australian/New Zealand Wiring Rules (AS/NZS 3000:2007). These are as follows:
Zone 0 - This covers interior area of the base of the bath or shower.
Zone 1 - This zone is divided into three sections, depending on what you have installed:
Zone 2 - This is the area with a horizontal radius of 0.6m out from Zone 1, and a height of 2.25m above the floor (or to the ceiling, whichever is lower).
Zone 3 - This is the area with a horizontal radius of 2.4m out from Zone 2. The vertical boundaries of this area extend from floor to ceiling or up to 2.5m above the floor, whichever is lower